<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>The Containment Chronicles</title>
	<atom:link href="http://blog.polargy.com/?feed=rss2" rel="self" type="application/rss+xml" />
	<link>http://blog.polargy.com</link>
	<description>Experiences in hot and cold aisle containment</description>
	<lastBuildDate>Wed, 07 Mar 2012 01:07:41 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.2.1</generator>
		<item>
		<title>San Diego Gets Hot</title>
		<link>http://blog.polargy.com/?p=175</link>
		<comments>http://blog.polargy.com/?p=175#comments</comments>
		<pubDate>Wed, 07 Mar 2012 01:07:41 +0000</pubDate>
		<dc:creator>Cary</dc:creator>
				<category><![CDATA[Installations]]></category>
		<category><![CDATA[New Construction]]></category>

		<guid isPermaLink="false">http://blog.polargy.com/?p=175</guid>
		<description><![CDATA[We recently finished a new construction Hot Aisle Containment project for a health care company in San Diego. We worked with a Design/Build firm who prepared the below plans. &#160; Polargy created shop drawings from these plans to prepare a &#8230; <a href="http://blog.polargy.com/?p=175">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<p>We recently finished a new construction Hot Aisle Containment project for a health care company in San Diego. We worked with a Design/Build firm who prepared the below plans.</p>
<div id="attachment_176" class="wp-caption aligncenter" style="width: 593px"><a href="http://blog.polargy.com/wp-content/uploads/2012/03/pod-layout.png"><img class="size-full wp-image-176" title="pod layout" src="http://blog.polargy.com/wp-content/uploads/2012/03/pod-layout.png" alt="" width="583" height="364" /></a><p class="wp-caption-text">Plan View Drawings for Hot Aisle Containment Layout</p></div>
<p>&nbsp;</p>
<p>Polargy created shop drawings from these plans to prepare a material list and installation instructions.</p>
<div id="attachment_177" class="wp-caption aligncenter" style="width: 495px"><a href="http://blog.polargy.com/wp-content/uploads/2012/03/pod-design.png"><img class="size-full wp-image-177" title="pod design" src="http://blog.polargy.com/wp-content/uploads/2012/03/pod-design.png" alt="" width="485" height="378" /></a><p class="wp-caption-text">Shop Drawing of Hot Aisle Containment</p></div>
<p>&nbsp;</p>
<p>The finished project looks great.</p>
<div id="attachment_178" class="wp-caption aligncenter" style="width: 594px"><a href="http://blog.polargy.com/wp-content/uploads/2012/03/Completed-Pod-1.jpg"><img class="size-large wp-image-178" title="Completed Pod 1" src="http://blog.polargy.com/wp-content/uploads/2012/03/Completed-Pod-1-768x1024.jpg" alt="" width="584" height="778" /></a><p class="wp-caption-text">San Diego Hot Aisle Containment</p></div>
<p>&nbsp;</p>
<p>Here is another view.</p>
<div id="attachment_179" class="wp-caption aligncenter" style="width: 594px"><a href="http://blog.polargy.com/wp-content/uploads/2012/03/Completed-Pod-3.jpg"><img class="size-large wp-image-179" title="Completed Pod 3" src="http://blog.polargy.com/wp-content/uploads/2012/03/Completed-Pod-3-1024x768.jpg" alt="" width="584" height="438" /></a><p class="wp-caption-text">San Diego Hot Aisle Containment Corner View</p></div>
]]></content:encoded>
			<wfw:commentRss>http://blog.polargy.com/?feed=rss2&#038;p=175</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Quick Wins Are Always Nice</title>
		<link>http://blog.polargy.com/?p=165</link>
		<comments>http://blog.polargy.com/?p=165#comments</comments>
		<pubDate>Wed, 08 Feb 2012 21:08:54 +0000</pubDate>
		<dc:creator>Cary</dc:creator>
				<category><![CDATA[Retrofits]]></category>
		<category><![CDATA[ROI Case Studies]]></category>

		<guid isPermaLink="false">http://blog.polargy.com/?p=165</guid>
		<description><![CDATA[&#8220;I just thought I’d let you know that we got the Polargy doors and top panels installed today, and saw an immediate drop of about 8-10 F in the cold aisle.&#8221;]]></description>
			<content:encoded><![CDATA[<p>&#8220;I just thought I’d let you know that we got the <a title="Polargy" href="http://www.polargy.com" target="_blank">Polargy</a> doors and top panels installed today, and saw an immediate drop of about 8-10 F in the cold aisle.&#8221;</p>
<div id="attachment_166" class="wp-caption aligncenter" style="width: 594px"><a href="http://blog.polargy.com/wp-content/uploads/2012/02/Cold_Aisle_Interior.jpg"><img class="size-large wp-image-166" title="Cold Aisle Containment" src="http://blog.polargy.com/wp-content/uploads/2012/02/Cold_Aisle_Interior-768x1024.jpg" alt="Cold Aisle Containment Polargy" width="584" height="778" /></a><p class="wp-caption-text">Cold Aisle Containment</p></div>
]]></content:encoded>
			<wfw:commentRss>http://blog.polargy.com/?feed=rss2&#038;p=165</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>?#@*&amp;%! Side-to-Side Air</title>
		<link>http://blog.polargy.com/?p=138</link>
		<comments>http://blog.polargy.com/?p=138#comments</comments>
		<pubDate>Tue, 29 Nov 2011 06:47:28 +0000</pubDate>
		<dc:creator>Cary</dc:creator>
				<category><![CDATA[Installations]]></category>
		<category><![CDATA[Retrofits]]></category>

		<guid isPermaLink="false">http://blog.polargy.com/?p=138</guid>
		<description><![CDATA[We all continue to struggle with containing &#8220;side-to-side&#8221; air on the 6500s. We stumbled upon this fix last year in San Jose, CA. The owner reports sufficient air supply with this simple hose and manifold set up. Here is a &#8230; <a href="http://blog.polargy.com/?p=138">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<p>We all continue to struggle with containing &#8220;side-to-side&#8221; air on the 6500s. We stumbled upon this fix last year in San Jose, CA. The owner reports sufficient air supply with this simple hose and manifold set up.</p>
<div id="attachment_140" class="wp-caption aligncenter" style="width: 594px"><img class="size-large wp-image-140" title="6500air3" src="http://blog.polargy.com/wp-content/uploads/2011/11/6500air31-1024x612.jpg" alt="" width="584" height="349" /><p class="wp-caption-text">Cold Air Piped into Cisco 6500s</p></div>
<div id="attachment_141" class="wp-caption aligncenter" style="width: 594px"><img class="size-large wp-image-141" title="6500air1" src="http://blog.polargy.com/wp-content/uploads/2011/11/6500air1-612x1024.jpg" alt="" width="584" height="977" /><p class="wp-caption-text">Is that my dryer exhaust hose?</p></div>
<p>Here is a little less sophisticated approach on a newer switch at a site in New Jersey.</p>
<div id="attachment_146" class="wp-caption aligncenter" style="width: 594px"><img class="size-large wp-image-146" title="IMAG0619" src="http://blog.polargy.com/wp-content/uploads/2011/11/IMAG0619-612x1024.jpg" alt="" width="584" height="977" /><p class="wp-caption-text">HP Launches New Air Containment Product</p></div>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://blog.polargy.com/?feed=rss2&#038;p=138</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Canada Keeps Cool</title>
		<link>http://blog.polargy.com/?p=154</link>
		<comments>http://blog.polargy.com/?p=154#comments</comments>
		<pubDate>Mon, 28 Nov 2011 20:22:18 +0000</pubDate>
		<dc:creator>Cary</dc:creator>
				<category><![CDATA[Installations]]></category>
		<category><![CDATA[ROI Case Studies]]></category>

		<guid isPermaLink="false">http://blog.polargy.com/?p=154</guid>
		<description><![CDATA[In 2011 Polargy installed a Cold Aisle Containment System for the Government of Canada. Below is a note and photos from the Data Center Manager who is a very satisfied customer. &#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;- Good Morning Cary, I only have good things &#8230; <a href="http://blog.polargy.com/?p=154">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<p>In 2011 Polargy installed a Cold Aisle Containment System for the Government of Canada. Below is a note and photos from the Data Center Manager who is a very satisfied customer.</p>
<p>&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;&#8212;-</p>
<p>Good Morning Cary,</p>
<p>I only have good things to say about your product. It solved our cooling issues in a snap!!!</p>
<p>We only went with your product after studying all alternative. One main feature of your product is the simplicity of the system and the ease to work with it during installation (minutes) and when maintenance have to be perform in the Data Center where the top panels have to be moved around. It proved such a success with all our staff. For the one concern about aesthetic, well the design is pretty slick if you ask me.</p>
<p>I don&#8217;t have the official tally from the CRAC units but my first investigation show that we are now saving more then 50% from our past cooling needs.</p>
<p>As we continue our expansion, you will hear from us in the future</p>
<p>Sincerely</p>
<p>Louis Hall</p>
<p>Moncton Data Centre / Centre Informatique de Moncton<br />
Infrastructure Services / Services d&#8217;infrastructure<br />
Innovation, Information and Technology / Innovation, information et technologie<br />
Human Resources and Skills Development Canada / Ressources humaines et Développement des compétences Canada<br />
Government of Canada / Gouvernement du Canada</p>
<p>&nbsp;</p>
<div id="attachment_155" class="wp-caption aligncenter" style="width: 594px"><a href="http://blog.polargy.com/wp-content/uploads/2011/12/CAC-POD3.jpg"><img class="size-large wp-image-155" title="Government of Canada Cold AIsle Containment 3" src="http://blog.polargy.com/wp-content/uploads/2011/12/CAC-POD3-1024x768.jpg" alt="Government of Canada Cold AIsle Containment 3" width="584" height="438" /></a><p class="wp-caption-text">Government of Canada Cold Aisle Containment </p></div>
<p>&nbsp;</p>
<div id="attachment_156" class="wp-caption aligncenter" style="width: 594px"><a href="http://blog.polargy.com/wp-content/uploads/2011/12/CAC-POD1.jpg"><img class="size-large wp-image-156" title="Government of Canada Inside Cold Aisle Containment Pod" src="http://blog.polargy.com/wp-content/uploads/2011/12/CAC-POD1-768x1024.jpg" alt="Government of Canada Inside Cold Aisle Containment Pod" width="584" height="778" /></a><p class="wp-caption-text">Government of Canada Inside Cold Aisle Containment Pod</p></div>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://blog.polargy.com/?feed=rss2&#038;p=154</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>It&#8217;s Cold in Jamaica</title>
		<link>http://blog.polargy.com/?p=88</link>
		<comments>http://blog.polargy.com/?p=88#comments</comments>
		<pubDate>Sat, 22 Oct 2011 20:09:28 +0000</pubDate>
		<dc:creator>Cary</dc:creator>
				<category><![CDATA[Installations]]></category>
		<category><![CDATA[Retrofits]]></category>

		<guid isPermaLink="false">http://blog.polargy.com/?p=88</guid>
		<description><![CDATA[Power is expensive in the Caribbean so data center efficiency is all the more important. Modern Power and Cooling Technology Limited successfully designed and implemented a cold aisle containment solution at the state of the art tier 3 Digicel Collocation &#8230; <a href="http://blog.polargy.com/?p=88">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<p>Power is expensive in the Caribbean so data center efficiency is all the more important. Modern Power and Cooling Technology Limited successfully designed and implemented a cold aisle containment solution at the state of the art tier 3 Digicel Collocation Facility at Caymans using <a title="Polargy Aisle Containment System" href="http://www.polargy.com/products/polarplex/index.php">Polargy&#8217;s Aisle Containment System </a>with the one of a kind “drop away” panel. A few classic site conditions were columns down the aisles, uneven aisle ends, and a single sided aisle. What is most impressive is that the design was done locally by Modern Power and they installed the system with no difficulties.</p>
<div id="attachment_89" class="wp-caption aligncenter" style="width: 625px"><img class="size-full wp-image-89" title="Cold Aisle Roof" src="http://blog.polargy.com/wp-content/uploads/2011/11/Screen-shot-2011-09-28-at-9.55.28-PM1.png" alt="Cold AIsle Containment Roof" width="615" height="460" /><p class="wp-caption-text">Cold Aisle Roof</p></div>
<div id="attachment_93" class="wp-caption aligncenter" style="width: 604px"><img class="size-full wp-image-93" title="Inside the cold aisle" src="http://blog.polargy.com/wp-content/uploads/2011/11/Screen-shot-2011-09-28-at-9.57.24-PM2.png" alt="Inside the contained cold aisle" width="594" height="457" /><p class="wp-caption-text">Inside the isolated cold aisle</p></div>
<p>Go to <a title="Modern Press release on Polargy" href="http://www.modernpowerja.com/index.php?option=com_content&amp;view=article&amp;id=34:mpc-installs-first-tier-3-cold-aisle-solution-using-polargy-caontainment-systems&amp;catid=3:news-&amp;Itemid=28">Modern&#8217;s Press Release</a> to see more details.</p>
]]></content:encoded>
			<wfw:commentRss>http://blog.polargy.com/?feed=rss2&#038;p=88</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Xcel Energy&#8217;s $169,000 Rebate Check</title>
		<link>http://blog.polargy.com/?p=127</link>
		<comments>http://blog.polargy.com/?p=127#comments</comments>
		<pubDate>Thu, 17 Feb 2011 19:47:11 +0000</pubDate>
		<dc:creator>Cary</dc:creator>
				<category><![CDATA[Retrofits]]></category>
		<category><![CDATA[ROI Case Studies]]></category>
		<category><![CDATA[Utility Rebates and Incentives]]></category>

		<guid isPermaLink="false">http://blog.polargy.com/?p=127</guid>
		<description><![CDATA[What a great outcome, the CFO must be thrilled. This cold aisle containment project enjoyed pure simplicity. The site, near Denver, was purpose built so Xcel Energy could just take a before and after meter reading for the entire building. &#8230; <a href="http://blog.polargy.com/?p=127">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<p>What a great outcome, the CFO must be thrilled.</p>
<div id="attachment_128" class="wp-caption aligncenter" style="width: 594px"><img class="size-large wp-image-128" title="XCEL Energy Rebate Check" src="http://blog.polargy.com/wp-content/uploads/2011/11/XCEL-Energy-Rebate-Check-1024x424.png" alt="Xcel energy rebate check for containment project" width="584" height="241" /><p class="wp-caption-text">Big Fat Rebate Check</p></div>
<p>This cold aisle containment project enjoyed pure simplicity.</p>
<p>The site, near Denver, was purpose built so Xcel Energy could just take a before and after meter reading for the entire building. The IT load did not really change over the course of the project, so the reduction was attributed to the shutting off of 39 CRAC units out of 70 units running. This <strong>reduction was measured at 435kW</strong>, or about 11kW per CRAC unit. These CRAC units were the old AirFlow brand and the per unit reduction was higher than anticipated but we double checked the meter readings and verified the constant IT load (via the UPS) to confirm the numbers.</p>
<div id="attachment_129" class="wp-caption aligncenter" style="width: 310px"><img class="size-medium wp-image-129" title="Airflow CRAC badge" src="http://blog.polargy.com/wp-content/uploads/2011/11/Airflow-CRAC-badge-300x225.jpg" alt="Airflow CRAC label" width="300" height="225" /><p class="wp-caption-text">Old Airflow CRAC Badge</p></div>
<p>The containment was a combination of cold aisle containment, under floor partitions, and CRAC unit extensions.<strong> PUE before was 2.0, after it was 1.8.</strong></p>
<p><a title="Polargy ROI" href="http://www.polargy.com/solutions/roi-and-rebates.php" target="_blank">Polargy helped calculate the ROI</a>. The project&#8217;s net costs were $400K ($569K less $169K). The 435kW savings yielded $225K annually (power rate is about 6 cents per kWh). This results in a project <strong>payback period of 1.6 years</strong>.</p>
]]></content:encoded>
			<wfw:commentRss>http://blog.polargy.com/?feed=rss2&#038;p=127</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Vanderbilt Shows Off at AFCOM</title>
		<link>http://blog.polargy.com/?p=54</link>
		<comments>http://blog.polargy.com/?p=54#comments</comments>
		<pubDate>Mon, 22 Mar 2010 22:24:17 +0000</pubDate>
		<dc:creator>Cary</dc:creator>
				<category><![CDATA[Installations]]></category>
		<category><![CDATA[Retrofits]]></category>
		<category><![CDATA[AFCOM]]></category>

		<guid isPermaLink="false">http://blog.polargy.com/?p=54</guid>
		<description><![CDATA[Vanderbilt contributed to the AFCOM event with a tour of its latest energy savings efforts in its Nashville data center. The university installed Polargy&#8217;s Cold Aisle Containment System on one of its newly installed aisles. 73 people toured through the &#8230; <a href="http://blog.polargy.com/?p=54">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<p>Vanderbilt contributed to the AFCOM event with a tour of its latest energy savings efforts in its Nashville data center. The university installed Polargy&#8217;s Cold Aisle Containment System on one of its newly installed aisles. 73 people toured through the site and experienced the containment system as shown below.</p>
<p>Our friend Jeff showing how the sliding door works:</p>
<p><object width="425" height="344" classid="clsid:d27cdb6e-ae6d-11cf-96b8-444553540000" codebase="http://download.macromedia.com/pub/shockwave/cabs/flash/swflash.cab#version=6,0,40,0"><param name="allowFullScreen" value="true" /><param name="allowscriptaccess" value="always" /><param name="src" value="http://www.youtube.com/v/kkhKi3JgoUM&amp;hl=en_US&amp;fs=1&amp;rel=0&amp;hd=1" /><param name="allowfullscreen" value="true" /><embed width="425" height="344" type="application/x-shockwave-flash" src="http://www.youtube.com/v/kkhKi3JgoUM&amp;hl=en_US&amp;fs=1&amp;rel=0&amp;hd=1" allowFullScreen="true" allowscriptaccess="always" allowfullscreen="true" /></object></p>
<p>Taking a peak inside the contained cold aisle. The site has a glass brick wall which is illuminating the wall above the CRAC unit, a neat look.</p>
<div id="attachment_107" class="wp-caption aligncenter" style="width: 1530px"><img class="size-full wp-image-107" title="vanderbilt22" src="http://blog.polargy.com/wp-content/uploads/2010/03/vanderbilt22.jpg" alt="Inside view of cold aisle with roof" width="1520" height="2032" /><p class="wp-caption-text">Inside the Aisle</p></div>
]]></content:encoded>
			<wfw:commentRss>http://blog.polargy.com/?feed=rss2&#038;p=54</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Pixar&#8217;s &#8220;Ridiculous&#8221; ROI on Cold Aisle Containment</title>
		<link>http://blog.polargy.com/?p=45</link>
		<comments>http://blog.polargy.com/?p=45#comments</comments>
		<pubDate>Sun, 31 Jan 2010 20:44:20 +0000</pubDate>
		<dc:creator>Cary</dc:creator>
				<category><![CDATA[Retrofits]]></category>
		<category><![CDATA[ROI Case Studies]]></category>
		<category><![CDATA[Utility Rebates and Incentives]]></category>
		<category><![CDATA[Cold Aisle Containment]]></category>
		<category><![CDATA[Retrofit]]></category>

		<guid isPermaLink="false">http://blog.polargy.com/?p=45</guid>
		<description><![CDATA[Jay (now at Twitter) presented Pixar&#8217;s results from Polargy&#8217;s Cold Aisle Containment installation. This is a simple and compelling story on containment&#8217;s ease of implementation and rapid ROI.]]></description>
			<content:encoded><![CDATA[<p>Jay (now at Twitter) presented Pixar&#8217;s results from Polargy&#8217;s Cold Aisle Containment installation. This is a simple and compelling story on containment&#8217;s ease of implementation and rapid ROI.</p>
<p><object width="425" height="344" classid="clsid:d27cdb6e-ae6d-11cf-96b8-444553540000" codebase="http://download.macromedia.com/pub/shockwave/cabs/flash/swflash.cab#version=6,0,40,0"><param name="allowFullScreen" value="true" /><param name="allowscriptaccess" value="always" /><param name="src" value="http://www.youtube.com/v/eUbtBce8P64&amp;hl=en_US&amp;fs=1&amp;rel=0" /><param name="allowfullscreen" value="true" /><embed width="425" height="344" type="application/x-shockwave-flash" src="http://www.youtube.com/v/eUbtBce8P64&amp;hl=en_US&amp;fs=1&amp;rel=0" allowFullScreen="true" allowscriptaccess="always" allowfullscreen="true" /></object></p>
]]></content:encoded>
			<wfw:commentRss>http://blog.polargy.com/?feed=rss2&#038;p=45</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Bernoulli Makes Curtains Dance</title>
		<link>http://blog.polargy.com/?p=32</link>
		<comments>http://blog.polargy.com/?p=32#comments</comments>
		<pubDate>Sat, 31 Oct 2009 20:17:41 +0000</pubDate>
		<dc:creator>Cary</dc:creator>
				<category><![CDATA[Retrofits]]></category>
		<category><![CDATA[Site Insights]]></category>
		<category><![CDATA[Cold Aisle Containment]]></category>
		<category><![CDATA[Retrofit]]></category>

		<guid isPermaLink="false">http://blog.polargy.com/?p=32</guid>
		<description><![CDATA[One problem we have seen with curtains on cold aisles is the flapping or drawing in of the curtains due to the airflow through the adjacent perforated tiles. Sometimes people call this the &#8220;dancing curtain problem.&#8221; The Bernoulli effect (air &#8230; <a href="http://blog.polargy.com/?p=32">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<p>One problem we have seen with curtains on cold aisles is the flapping or drawing in of the curtains due to the airflow through the adjacent perforated tiles. Sometimes people call this the <strong>&#8220;dancing curtain problem.&#8221;</strong> The Bernoulli effect (air plane wing effect) of lower pressure on the side of the higher air velocity causes this. This flapping can push the curtains close to the server intakes and then the suction of the intakes can suck the curtains onto them, blocking and essentially starving the servers. We caught this blocking three times before we adopted a policy of avoiding curtains on cold aisles.</p>
<p><iframe width="584" height="438" src="http://www.youtube.com/embed/TOpUotKZF0M?fs=1&#038;feature=oembed" frameborder="0" allowfullscreen></iframe></p>
<p>After examining this and having the good fortune of a customer doing some testing we concluded that flapping curtains are not a fuction of air balance in the contained zone. Rather, it is a function of turbulence caused by the airflow through the nearby tiles. So, even if one has an oversupply of air, the curtains just don&#8217;t push out gently as one might expect.</p>
<p>We tried adding weights to the curtains to prevent their movement, but this only resulted in heavy flying objects banging into the servers. Ultimately, we added two solid panels to the sides of the strip door. By the time we did this, the cost was about the same as a sliding door like the one pictured below.</p>
<div id="attachment_111" class="wp-caption aligncenter" style="width: 2861px"><img class="size-full wp-image-111 " title="sliding door" src="http://blog.polargy.com/wp-content/uploads/2009/10/sliding-door.jpg" alt="" width="2851" height="1901" /><p class="wp-caption-text">Sliding Door Preferred Over Curtains for CAC</p></div>
<p>The design approaches to combat the flapping curtains include:</p>
<ul>
<li>Hot aisle containment &#8211; there is no air flow from the floor</li>
<li>Sliding doors &#8211; they don&#8217;t move</li>
<li>Solid floor tiles at ends of rows &#8211; no nearby air movement</li>
<li>Extended containment perimeter &#8211; basically place doors away from aisle end in some manner</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://blog.polargy.com/?feed=rss2&#038;p=32</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Containment&#8217;s Gas Suppression Challenge</title>
		<link>http://blog.polargy.com/?p=25</link>
		<comments>http://blog.polargy.com/?p=25#comments</comments>
		<pubDate>Sat, 31 Oct 2009 19:47:42 +0000</pubDate>
		<dc:creator>Cary</dc:creator>
				<category><![CDATA[Fire Safety]]></category>
		<category><![CDATA[Retrofits]]></category>
		<category><![CDATA[Retrofit]]></category>

		<guid isPermaLink="false">http://blog.polargy.com/?p=25</guid>
		<description><![CDATA[Existing data centers protected with FM200 or other clean agent systems can be a challenge to contain because the cost of adding or moving nozzles is very high. One alternative has been the use of electronic fuse links that trigger &#8230; <a href="http://blog.polargy.com/?p=25">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<p>Existing data centers protected with FM200 or other clean agent systems can be a challenge to contain because the cost of adding or moving nozzles is very high. One alternative has been the use of electronic fuse links that trigger off the FM200 system. Though the links are pricey (about $250 each) and need testing, it is a workable solution that can still offer an ROI that meets project goals.</p>
<div id="attachment_26" class="wp-caption alignnone" style="width: 310px"><img class="size-medium wp-image-26 " title="containment fuse link" src="http://blog.polargy.com/wp-content/uploads/2009/10/DSCN4567-300x225.jpg" alt="Electronic Fuse Links" width="300" height="225" /><p class="wp-caption-text">Electronic Fuse Links</p></div>
<p>The electronic links pictured above where installed on a hot aisle containment system pictured below. The site has a ceiling with two levels and the FM200 nozzles are installed in the lower section of the ceiling. The curtains were installed with a gap above them to allow some air movement (so not total isolation) in order to assure that air flow to the existing smoke detectors were not obstructed.</p>
<div id="attachment_27" class="wp-caption alignnone" style="width: 310px"><img class="size-medium wp-image-27" title="DSCN4564" src="http://blog.polargy.com/wp-content/uploads/2009/10/DSCN4564-300x225.jpg" alt="Hot Aisle Containment" width="300" height="225" /><p class="wp-caption-text">Hot Aisle Containment</p></div>
<p>These links have an electronic trigger off a signal from the FM200 system as well as a thermally activated mechanism. The wiring requirements are similar to those for smoke detectors and is through conduit that you can see in the above picture. The other wires are tethers to stop the fall of the curtain after it drops about two feet to clear the FM200 nozzles.</p>
]]></content:encoded>
			<wfw:commentRss>http://blog.polargy.com/?feed=rss2&#038;p=25</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

